DSpace Repository

Chemical-effect variation of Kß/K? X-ray intensity ratios in 3d elements

Show simple item record

dc.contributor.author Sogut, O.
dc.contributor.author Büyükkasap, E.
dc.contributor.author Erdoğan, Hasan
dc.date.accessioned 2019-08-16T11:45:54Z
dc.date.available 2019-08-16T11:45:54Z
dc.date.issued 2002
dc.identifier.issn 0969-806X
dc.identifier.uri https://hdl.handle.net/11499/5377
dc.identifier.uri https://doi.org/10.1016/S0969-806X(01)00644-2
dc.description.abstract Chemical effects on Kß/K? X-ray intensity ratios for some Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn compounds are studied experimentally. The X-ray spectra were measured by using a Si (Li) solid state detector with high resolution. The vacancies were produced by heavily filtered 241Am gamma rays. It is found that the Kß/K? X-ray intensity ratios measured with compounds deviated up to 43% from the corresponding values of the pure elements. The values for pure elements are compared with the other experimental and with theoretical values. © 2002 Elsevier Science Ltd. All rights reserved. en_US
dc.language.iso en en_US
dc.relation.ispartof Radiation Physics and Chemistry en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Chemical effect en_US
dc.subject X-ray intensity ratios en_US
dc.subject Gamma rays en_US
dc.subject Iron en_US
dc.subject X ray analysis en_US
dc.subject Solid states detectors en_US
dc.subject Titanium en_US
dc.subject chromium en_US
dc.subject cobalt en_US
dc.subject copper en_US
dc.subject element en_US
dc.subject iron en_US
dc.subject lithium en_US
dc.subject manganese en_US
dc.subject nickel en_US
dc.subject silicon en_US
dc.subject titanium en_US
dc.subject vanadium en_US
dc.subject zinc en_US
dc.subject article en_US
dc.subject experimentation en_US
dc.subject gamma radiation en_US
dc.subject solid state en_US
dc.subject X ray spectrometry en_US
dc.title Chemical-effect variation of Kß/K? X-ray intensity ratios in 3d elements en_US
dc.title.alternative Chemical-effect variation of K beta/K alpha X-ray intensity ratios in 3d elements en_US
dc.type Article en_US
dc.identifier.volume 64 en_US
dc.identifier.issue 5-6 en_US
dc.identifier.startpage 343
dc.identifier.startpage 343 en_US
dc.identifier.endpage 348 en_US
dc.identifier.doi 10.1016/S0969-806X(01)00644-2
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.identifier.scopus 2-s2.0-0036095230 en_US
dc.identifier.wos WOS:000176825200002 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record