Abstract:
Chemical effects on Kß/K? X-ray intensity ratios for some Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn compounds are studied experimentally. The X-ray spectra were measured by using a Si (Li) solid state detector with high resolution. The vacancies were produced by heavily filtered 241Am gamma rays. It is found that the Kß/K? X-ray intensity ratios measured with compounds deviated up to 43% from the corresponding values of the pure elements. The values for pure elements are compared with the other experimental and with theoretical values. © 2002 Elsevier Science Ltd. All rights reserved.