dc.description.abstract Objective: The presence of metallic impurities can pose a se-rious concern due to their interaction with receptor-specific biomolecules that require the highest possible specific activity, especially in radioactive labeling. There are studies in which Zn and other toxic metal pollution increases if the generator is not used for a long time. In this study the effect of pre-elution on chemical and radiochemical impurities in the synthesis product was investigated. Material and Methods: In the study, 68GaPSMA-11 labeling was performed with the generator eluate that was not used for one month (sample 1). A blank elution was taken 24 hours after using the generator (sample 2). In the next 24 hours, the second 68GaPSMA-11 labeling was performed (sample 3). Six hours after this labeling, another 68GaPSMA-11 synthesis was performed (sample 4). Eluates were analyzed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Results: Results was reported as a table in mu g/ml. 68Ge levels determined at 0.018 ppm, 0.012 ppm and 0.009 ppm levels in the labeled products were determined below the pharmacopoeia limits. Zn(II) impurities were found as 0.625 ppm in the labeling performed without generator pre-elution. In generator pre-eluted labelings; Zn(II) impurities were determined as 0.133 ppm and 0.108 ppm. Conclusion: Pre-elution of the generator prior to synthesis does not seem to be a chemical requirement other than zinc pollution. 68GaPSMA-11 can be pre-eluted for high labeling efficiency, but it is thought that pre-elution is not significant in terms of chemical and radiochemical contamination. en_US
dc.language.iso en en_US
dc.publisher Istanbul Univ, Fac Medicine, Publ Off en_US
dc.relation.ispartof Journal Of Istanbul Faculty Of Medicine-Istanbul Tip Fakultesi Dergisi en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Radiopharmaceutical product en_US
dc.subject (68)GaPSMA-11 en_US
dc.subject metallic impurities en_US
dc.subject Ge-68/Ga-68 generator en_US
dc.subject Biodistribution en_US
dc.subject Ga-68 en_US
dc.title EVALUATION OF (GeGa)-Ge-68-Ga-/68 GENERATOR PRE-ELUTION EFFICIENCY ON METALLIC IMPURITIES IN THE COMPOSITION OF(68)GaPSMA-11 RADIOPHARMACEUTICAL IN NUCLEAR MEDICINE PET CHEMISTRY en_US
dc.type Article en_US
dc.identifier.volume 84 en_US
dc.identifier.issue 4 en_US
dc.identifier.startpage 526 en_US
dc.identifier.endpage 530 en_US
dc.identifier.doi 10.26650/IUITFD.2021.872398
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.authorscopusid 56258662100
dc.authorscopusid 6701446280
dc.authorwosid Uğur, Ayşe/ABE-7866-2021
dc.department-temp [Ugur, Ayse; Yuksel, Dogangun] Pamukkale Univ, Educ & Res Hosp, Dept Nucl Med, Denizli, Turkey en_US
dc.identifier.scopus 2-s2.0-85130918685 en_US
dc.identifier.trdizinid 484029 en_US
dc.identifier.wos WOS:000704257000014 en_US


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record